CHAPTER 13 RESET FUNCTION

The following two operations are available to generate reset signals.

(1) External reset input via RESET pin

(2) Internal reset by inadvertent program loop time detected by watchdog timer

External and internal reset have no functional differences. In both cases, program execution starts at the address

at 0000H and 0001H by RESET input.

When a low level is input to the RESET pin or the watchdog timer overflows, a reset is applied and each of the

hardware is set to the status shown in Table 13-1. Each pin is high impedance during reset input or during the

oscillation stabilization time just after reset release.

When a high level is input to the RESET pin, the reset is released and program execution is started after the

oscillation stabilization time (2

15

/fx) has elapsed. The reset applied by watchdog timer overflow is automatically

released after reset, and program execution is started after the oscillation stabilization time (2

15

/fx) has elapsed (see

Figures 13-2 through 13-4.)

Cautions

1. For an external reset, input a low level for 10

µµµµs or more to the RESET pin.

2. When the STOP mode is released by reset, the STOP mode contents are held during reset

input. However, the port pins become high impedance.

Figure 13-1. Block Diagram of Reset Function

RESET

Interrupt function

Count clock

Reset controller

Watchdog timer

Over-
flow

Reset signal

Stop