2 register controlling standby function – NEC switch User Manual

Page 179

Advertising
background image

CHAPTER 12 STANDBY FUNCTION

User’s Manual U12978EJ3V0UD

179

12.1.2 Register controlling standby function

The wait time after the STOP mode is released upon interrupt request until oscillation stabilizes is controlled with

the oscillation stabilization time select register (OSTS).

OSTS is set with an 8-bit memory manipulation instruction.

RESET input sets OSTS to 04H. However, it takes 2

15

/f

X

until oscillation stabilizes after RESET input.

Figure 12-1. Format of Oscillation Stabilization Time Select Register

OSTS2

0

0

1

0

0

0

0

0

OSTS2 OSTS1 OSTS0

OSTS

R/W

FFFAH

04H

R/W

7

6

5

4

3

2

1

0

OSTS1

0

1

0

2

12

/f

X

2

15

/f

X

2

17

/f

X

(683 s)

(5.46 ms)

(21.8 ms)

OSTS0

0

0

0

Setting prohibited

Symbol

Address

After reset

Oscillation stabilization time selection

Other than above

µ

Caution

The wait time after the STOP mode is released does not include the time from STOP mode

release to clock oscillation start (“a” in the figure below), regardless of release by RESET input

or by interrupt generation.

STOP mode release

X1 pin voltage

waveform

a

Remarks 1. f

X

: System clock oscillation frequency

2. The parenthesized values apply to operation at f

X

= 6.0 MHz.

Advertising