Checking the communication state – NEC NEAX IPS NWA-008869-001 User Manual

Page 122

Advertising
background image

CHAPTER 4 INITIALIZATION

– 112 –

NWA-008869-001 Rev.1.0

atch4001.fm

Startup

Checking
Use the show running-config command to check the startup state of the telnet server.

Checking the communication state

Check the telnet communication inside the In-Skin Router and between remote consoles.

For checking, use the ping command for IPv4 and the ping6 command for IPv6, with the IP address of the
remote console specified. You can use the ping and ping6 commands in both global config mode and in-
terface config mode.

ix1000

− 01 (config − FastEthernet0.0) # exit

ix1000

− 01 (config) # telnet − server ip enable

ix1000

− 01 (config) #

Enter

Enter

ix1000

− 01 (config − FastEthernet0.0) # exit

ix1000

− 01 (config) # telnet − server ipv6 enable

ix1000

− 01 (config) #

Enter

Enter

ix1000

− 01 (config) # show running − config

(Omitted)

timezone + 9

telnet

− server ip enable

telnet

− server ipv6 enable

device FastEthernet0

device Ethernet0

Interface FastEthernet0.0

ip address 192.168.3.100/24

ipv6 address 3ffe : 200 : : 1/64

no shutdown

interface FastEthernet0.1

encapsulation pppoe

(Omitted)

ix1000

− 01 (config) #

Enter

Check that "enable" is

displayed.

SETUP FOR A REMOTE CONSOLE

Advertising