CHAPTER 2 INSTALLATION

– 51 –

NWA-008869-001 Rev.1.0

atch2001.fm

SW
(Piano Key SW)

1

NOTE 3

ON

Source clock signal from network is
sent to the PLO0 input on MP card.

OFF

Source clock signal from network is not
sent to the PLO0 input on MP card.

2

NOTE 3

ON

Source clock signal from network is
sent to the PLO1 input on MP card.

OFF

Source clock signal from network is not
sent to the PLO1 input on MP card.

3

ON

Remote loopback

For normal operation

4

ON

Local loopback (AIS send)

For normal operation

5

ON

Transmission line cable:
Coaxial cable (75

Ω)

Transmission line cable:
Twisted-pair cable (120

Ω)

6

Not used (Always set to OFF)

7

8

ON

AP No. 04-15

OFF

AP No. 20-31

Continued on next page

SWITCH NAME

SWITCH

NUMBER

SETTING

POSITION

FUNCTION

CHECK

OFF

ON

5

6

7

8

1

2

3

4

OFF

OFF

OFF

ON

OFF

INSTALLATION PROCEDURE