CHAPTER 2 INSTALLATION

– 64 –

NWA-008869-001 Rev.1.0

atch2001.fm

Cable Connection of WAN connector on PZ-M650 Card

Connect the WAN connector on the PZ-M650 card and the digital private line (E1).

PZ-M650 - Digital private network (E1) Cable Connection

PN-RTA

PZ-M650

WAN

8
7
6
5
4
3
2
1

E1 Network Cable
(Twisted-Pair Cable)

Digital Private Network (E1)

Not used
Not used
Not used
Tip (Transmit)
Ring (Transmit)
Not used
Tip (Receive)
Ring (Receive)

Pins (RJ-48C Connector)

Maximum 400 m (1310 ft.)

INSTALLATION PROCEDURE