NEC NEAX IPS NWA-008869-001 User Manual

Page 57

Advertising
background image

CHAPTER 2 INSTALLATION

– 47 –

NWA-008869-001 Rev.1.0

atch2001.fm

The figure in the SWITCH NAME column and the position of

in the SETTING POSITION col-

umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and

, the setting of the switch varies with the system concerned.

NOTE 1:

Set the groove on the switch to the desired position.

NOTE 2:

When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.

NOTE 3:

To receive a clock signal from MP card, set the SW0-1 and SW0-2 on all the DTI cards to
“OFF”.

NOTE 4:

This card must be reset after the SW0-3 to SW0-7 switch settings. Set the MB switch to UP and
then DOWN.

SWITCH NAME

SWITCH

NUMBER

SETTING

POSITION

FUNCTION

CHECK

MAS (Jumper pin)

UP

Clock Source

Clock Receiver

AISS (Jumper pin)

AIS signal is sent out when make-busy
or power on.

DOWN

AIS signal is not sent out when make-
busy or power on.

JP1 (Jumper pin)

Always set to LEFT

DOWN

UP

LEFT

INSTALLATION PROCEDURE