CHAPTER 2 INSTALLATION

– 40 –

NWA-008869-001 Rev.1.0

atch2001.fm

Switch Settings

The figure in the SWITCH NAME column and the position of

in the SETTING POSITION col-

umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and

, the setting of the switch varies with the system concerned.

Continued on next page

SWITCH NAME

SWITCH

NUMBER

SETTING

POSITION

FUNCTION

CHECK

SW
(Piano Key SW)

1

NOTE 1
NOTE 2

ON

Source clock signal from network is
sent to the PLO0 input on MP card
(2.0 MHz clock).

Source clock signal from network is not
sent to the PLO0 input on MP card
(2.0 MHz clock).

2

NOTE 1
NOTE 2

ON

Source clock signal from network is
sent to the PLO1 input on MP card
(2.0 MHz clock).

Source clock signal from network is not
sent to the PLO1 input on MP card
(2.0 MHz clock).

3

Not used

4

ON

WAN port or E1 interface for PBX are
available.

Only WAN port is available.

1

2

3

4

ON

OFF

OFF

OFF

OFF

INSTALLATION PROCEDURE