Clearing faults using remote console interface, Replacing the power supply – NEC ExpressA1160 User Manual
Page 224

Clearing Faults using remote console interface
11-28
replacing only one power supply.
1. Remove the power cable from the power supply.
2. While pressing the orange release lever toward the handle, pull the power supply
out of the cell using the handle.
Figure 11-23 Power Supply
11.15.2. Replacing the Power Supply
1. Slide the new power supply into the cell until it clicks in place and the locking latch
engages.
2. Connect the power cable to the power supply. The green status light illuminates to
indicate that the power supply is functioning properly.
11.16. Clearing Faults using remote console interface
After you investigate any faults that occur and replace the faulty hardware components,
you should clear faults from the partition, as follows:
1. Navigate to the fault information page of the partition remote console interface (refer
to
Figure 3-19
).
2. Click
Clear All
to clear all fault-related data, which performs the following actions:
y
Clears fault-related data for the partition
y
Clears EXPRESSSCOPE® Monitor LCDs and LEDs on all cells in the partition