Enabling and disabling components – NEC ExpressA1160 User Manual

Page 71

Advertising
background image

Partition Remote Console Interface

3-29

Figure 3-19 Clear Fault Data — Enable/Disable Components Page

Refer to

3.5.21 Enabling and Disabling Components

if you need to disable or enable

components manually.

Refer to

11.16 Clearing Faults using remote console interface

for a procedure to clear

faults after you replace faulty hardware components.

3.5.21. Enabling

and

Disabling Components

Partition components can become disabled automatically when faults occur. You also
can disable them manually to temporarily remove them from the partition. Disabled
components are not used the next time the partition is powered up or restarted.

To disable components manually

1. Navigate to the fault information page of the remote console interface for a partition

(refer to

Figure 3-19

).

The lower portion of the page lists components by cell and shows them as being
either enabled or disabled.

2. Scroll to each desired component and select Disabled.

3. Click

Submit

.

4. Power up the partition (or restart it if it is running) to boot it without the disabled

components.