G. Filling the Hopper with Fuel

NOTICE: RAISED PLATFORM INSTALLATIONS

Consideration must be given for fi lling the hopper with fuel
when determining the height of the raised platform. It must
not be so high that it interferes with the safety of fi lling the
hopper with fuel.

1. Start-Up Cycle

During this cycle:

• Igniter turns on for 90 seconds to heat up the air in the

fi repot

• Combustion blower starts

• Vacuum switch comes on

• Feed motor turns on adding fuel to the fi repot and the

appliance waits for the fi re to start

The duration of start-up depends on the type and quality
of fuel used. It is normal to see some smoke during the
ignition process as moisture evaporates and the fuel lights.
The smoke will stop once the fi re starts.

H. Starting Your First Fire

1. Fuel Selection

To start your fi rst fi re, you must:

• Select the appropriate fuel on the FUEL SELECTION screen

on the thermostat wall control to match the fuel you have
chosen to burn.

• If the proper fuel is not selected your appliance will not

operate properly.

• For example, if you have selected wood pellets and you are

burning corn, the appliance may not light, it may go out or
overfeed. Figure 10.1.

NOTE: If you are lighting your appliance for the fi rst time:

• The feed tube will be empty and it can take some time to fi ll

it with fuel before you will see a fi re

• Put a handful of fuel in the fi repot (priming) to speed up the

process. You can also do this when you have run com-
pletely out of fuel.

Sunflower Seeds

Corn
Utility Pellet
Softwood Pellet

Wheat
Hardwood Pellet

DONE

SELECT

FUEL SELECTION

I. Ignition Cycles

The fi replace engine is controlled by the digital thermostat
wall control. The digital display on the wall control will tell
you what your appliance is doing in the upper left corner
(System Status). Figure 10.3.

READY

73

Set at: 73

12:30 PM

HEAT OUTPUT

MENU

System Status

Every time the thermostat calls for heat, the appliance steps
through fi ve cycles:

1

Start-Up Cycle

4

Shutdown Cycle

2

Soft-Start Cycle

5

Auto-Clean Cycle

3

Heating Cycle

The duration and characteristics of these cycles may be dif-
ferent with each type of fuel selected.

2. Comfort Level Selection

Once your fuel is selected, select the temperature at the desired
setting on the SET COMFORT LEVEL screen. Figure 10.2.

3. Automatic or Manual Setting

The automatic setting will control the heat output based on
the comfort level selection. The manual setting allows you to
manually control the heat output settings.

Figure 10.2

Figure 10.3

Figure 10.1

WARNING! RISK OF FIRE!

Do NOT operate appliance:
• With appliance door open
• With fi repot fl oor open
• With ash pan removed
• Without the two slide rail attachment bolts secured to

fi replace

Check the hopper and make sure it is empty before fi lling
with fuel.

• Open the front to expose the hopper door. Pull down on the

hopper door to open and fi ll with fuel. The hopper door can
now serve as a shelf to support the bag of fuel

• Do not over fi ll the hopper. The hopper door must be com-

pletely closed to maintain proper vacuum and for the feed
motor to operate. An error ICON will appear on the wall
control if the hopper door is not properly closed.

• Do not leave any part of the fuel bag on the appliance after

fi lling hopper.