Warning, D. connecting wall control to fireplace – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 35

Advertising
background image

R

December 6, 2011

7051-158B

Page 35

EDGE 60 Pellet Fireplace

C. Junction Box & Wiring Diagram

1. There is a 5 screw terminal connection bar that is located

in the lower left side of the fi replace above the slide rails.
Figure 34.3.

2. Route the

25 foot (7.62m) long white

wall control wire that

is supplied in the component pack through the rubber
grommet in the left side of the fi replace outer can. Figure
34.1

3. The center 3 screws are for the thermostat wall control

wires and the 2 outer screws are mounting screws and
should not have wires attached to them.

The thermostat wires are color coded. The green wire
is on the top, the white in the middle and the red on the
bottom.

5. Attach the wall control wire to the thermostat wall control

Follow the directions on page 35. Do not pinch the con-
trol wires with any staples between the fi replace and wall
control. Figure 35.1 on page 35.

6. Bend back the 3 red spade connectors towards inside of

outer can and away from the fi replace. Wires should not
be in the way when the fi replace is rolled out on the rail
system.

D. Connecting Wall Control To Fireplace

Caution! The fi replace should be securely attached to the
fl oor prior to making fi nal electrical connections.

WARNING

Shock Hazard

• A grounded metal outlet power supply box is

required for all installations.

• Provides a positive ground path to earth for

outer can of the fi replace.

• Protects against possible electrical shock.

1. Disconnect power supply providing power to the outlet

box you intend to use.

2. The power supply cord is inside a 7-1/2 foot (2.29m)

long 3/8 inch (9.5mm) fl exible conduit cable located and
attached to the left side of the outer can. Figure 34.1.
The cable comes with an insulated snap-in connection.

3. Locate the metal outlet box within 7-1/2 feet (2.29m) of

the fi replace. (Note: Metal outlet box not supplied).

4. Feed the power cord into the 1/2 inch (12.7mm) standard

knockout of the outlet box and then press the connection
into the metal outlet box.

5. The power supply cord has black, white and green wires

to connect to the outlet box.

Black wire: Connects to 120V AC 15-20 amp circuit
White wire: Connects to neutral wire
Green wire: Connects to ground wire and outlet box

6. Ensure the 2 green grounding wires are securely attached

to the grounding screw. Figure 34.2.

Power Supply Cord inside 7.5 ft

(2.29m) Flexible Cable

Thermostat Wall Control Wire

Both Green Grounding Wires
Attach to Grounding Screw

Grounding

Screw

Black

Wires

White
Wires

Figure 34.1 - Power Supply Cord
and Wall Control Wire

Figure 34.2 - Metal Outlet Box

Green

White

Red

Matching

Color Dots

Fireplace Left Lower Front

Figure 34.3 - Terminal Connec-
tion Bar