E. Chimney and Exhaust Connection

1.

Chimney & Connector: Use 3 or 4 inch (76-102mm)
diameter type "L" or "PL" venting system. It can be vented
vertically or horizontally.

2. Mobile Home: Approved for all Listed pellet vent. As

with all installations a Quadra-Fire Outside Air Kit must
be used with manufactured home installations.

3

. INSTALL VENT AT CLEARANCES SPECIFIED BY THE

VENT MANUFACTURER.

4. Exhaust Venting System: Secure to the appliance with

at least 2 screws 180 degrees apart. Also secure all
connector pipe joints with at least 3 screws through each
joint.

NOTE: All pipe must be welded seam pipe whenever
possible. Seal pipe joints with high temperature silicone
(500°F [260°C] minimum rated only).

NOTE: If burning shelled fi eld corn, you must use
approved venting specifi cally designed for corn. Follow
the instructions from the venting manufacturer.

• Only LISTED venting components may be used.

• NO OTHER vent components may be used.

• Substitute or damaged vent components may impair

safe operation.

WARNING! RISK OF FIRE!

WARNING! RISK OF INJURY OR PROPERTY
DAMAGE!

• Improper installation, adjustment, alteration, service or

maintenance can cause injury or property damage.

• Refer to the owner’s information manual provided with this

appliance.

• For assistance or additional information consult a qualifi ed

installer, service agency or your dealer.

The table below can help you calculate the equivalent feet
of pipe which is a method used to determine pellet vent size.
Figure 40.1.

F. Equivalent Feet of Pipe

Figure 40.1

2 ft.

2 ft.

3 ft.

2 ft.

Example of 3 Elbow-Rear Vent Termination Calculation

Pellet Venting

Component

# of

Elbows

Feet of

Pipe

Multiplied

By

Equivalent

Feet

Components

Equivalent Feet

90

o

Elbow or Tee

3

X

5

15

45

o

Elbow

X

3

Horizontal Pipe

7

X

1

7

Vertical Pipe

2

X

0.5

1

Total Equivalent Feet

23

Note: This is a generic example and is not
intended to represent any specifi c fuel type.

Vent surfaces get HOT, can cause burns
if touched. Non-combustible shielding or
guards may be required.

WARNING