Maintaining & servicing your appliance, Edge 60 pellet fireplace, Before servicing your appliance – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 14

Advertising
background image

Page 14

7051-158B

December 6, 2011

R

EDGE 60 Pellet Fireplace

CAUTION! SHOCK AND SMOKE HAZARD!

• Proper Shutdown Procedure must be followed.

• Smoke spillage into room can occur if appliance is not

cool before turning off power switch.

• Risk of shock if appliance is not turned off before servic-

ing appliance.

A. Proper Shutdown Procedure

• Set wall control to OFF on AUTOMATIC / MANUAL SET-

TING screen. Figure 14.1.

• Wall control screen will scroll through the following mes-

sages after setting to OFF.

• Shutdown

• Auto-Clean

• Off

Before Servicing Your Appliance

Manual

Off

Automatic

Figure 14.1

3

Maintaining & Servicing Your Appliance

B. Quick Reference Maintenance Chart

NOTICE: These are recommendations. Clean more frequently if you encounter heavy

build-up of ash at the recommended interval or you see soot coming from the
vent. Not properly cleaning your appliance on a regular basis will void your
warranty
.

Approximately 45 minutes after setting the wall control to
OFF, the appliance should be cool enough to touch. If so,
now you can turn the power switch to OFF and pull the
appliance foward on the rails.

There is an interlock switch next to the power switch that as
you slide the appliance out it will ensure the auto-clean system
and the auger will not run, but the blowers will operate.

After servicing, restart with the AUTO/MANUAL SETTINGS
screen. Figure 14.1.

Follow the detailed instructions found in this
section for each step listed in the chart below.

Cleaning or Inspection

Frequency

Daily Weekly Every 2

Weeks

Monthly

Yearly

Ash Pan - Burning Wood Pellets

Every 5 bags of fuel

OR

X

Ash Pan - Burning Alternate Fuels

Every 1 bag of fuel

OR

X

Ash Removal from Firebox

More frequently depending on the
fuel type or ash build-up

OR

X

Auto-Clean Inspection

More frequently depending on the
fuel type

OR

X

Blower, Combustion (Exhaust)

More frequently depending on the
fuel type

OR

X

Blower, Convection

More frequently depending on the
operating environment

OR

X

Door Latch Inspection

Prior to heating season

OR

X

Firebox - Prepare for Non-Burn Season

At end of heating season

OR

X

Firepot - Burning Softwood Pellets

Every 5 bags

OR

X

Firepot - Burning Hardwood Pellets

Every 3 bags

OR

X

Firepot - Burning Alternate Fuels

Every 1 bag

OR

X

Glass

When clear view of fi repot
becomes obscured

OR

X

Heat Exchanger & Drop Tube

Every 1 ton of fuel

OR

X

Hopper

Every 1 ton of fuel or when chang-
ing fuel types

OR

X

Venting System

More frequently depending on the
fuel type

OR

X

Advertising