EDGE 60 Pellet Fireplace

E. Thermostat Wall Control Installation

Consideration should be given to the mounting material
when installing the wall control.

If mounting the wall control to a sheet rock surface you
should use the provided anchors for mounting.

If mounting the wall control to a wood surface or an electri-
cal outlet box then the fasteners provided will suffi ce and
the anchors need not be used.

1. Remove the front cover of the wall control by prying the
cover off with a small screwdriver or your fi ngernail. Place
the front side to the packaging to protect it from damage
while installing the sub base.

2. Route the wires into the wall control leaving only the
amount necessary to make the connection to the terminal
block in the upper left hand corner remaining. The wires are
routed to the terminal block according to the letters printed
in the thermostat sub base.

Red at the top
Green in the middle
White at the bottom

3. Push as much extra wire as possible back into the wall
and seal the hole in the wall with putty or insulation.

4. When re-installing the cover make sure that the wire
routing does not interfere with any of the components.
Make adjustments as needed and snap cover back into
place making sure that all locking tabs snap into place.

Red Wire

Top

Bottom

White Wire

Green Wire

Figure 35.1- Back Side of Wall Control with
Cover Off

F. Installing Flue Collar, Vertical or Horizontal

The fi replace ships from the factory without the fl ue collar
and gasket attached. They are located in the component
pack inside the fi rebox. Follow the steps below for a vertical
or horizontal installation.

Vertical Installation

1. Remove the fl ue collar and gasket from the component

pack. Push out the 6 slugs in the gasket.

2. Remove both the top and rear cover plates. Save screws

and plates for later re-attachment.

3. Place the orange fl ue gasket over the locating pins on

the exhaust fl ue transition on the back of the fi replace.
Figure 35.2.

4. Insert the fl ue pipe through the top cover plate.

5. Before inserting the fl ue collar into the pipe, liberally

silicone the end of the fl ue collar with Hi-Temp silicone
about 1-1/2 inches (38mm) wide. Figure 36.1 on page
36.

NOTE: You will need to install one section of 3 inch (76mm)
diameter vent pipe to clear the outer can cover plate before
installing a 3 to 4 inch (76-102mm) pellet pipe adapter for
the balance of the venting.

6. Lay the fi rst section of pipe on its side for screw attach-

ment. The 2 screws need to be directly above the locat-
ing pins, 180 degrees apart. Figure 36.2 on page 36.

7. Drill holes through the pipe walls directly into the fl ue

collar. Attach screws through pipe into fl ue collar.

8. Carefully feed the fl ue collar and pipe through the outer

can top fl ue opening and guide the fl ue collar base plate
over the 2 locating pins. Secure with 4 screws provided
in component pack.

9. Re-attach the top cover plate to the top of the fi replace

and the rear cover to the back of the outer can. Figure
36.4 on page 36.

NOTICE: The thermostat wall control should be mounted
on an inside wall and not in direct line with the appliance
convection air.

NOTICE: If the thermostat wall control is located too close
to the appliance, you may need to set the temperature setting
slightly higher to maintain the desired temperature in your
home.

Locating Pins

4 screws in outer corner holes

Figure 35.2- Install Orange Flue Gasket

Advertising