Edge 60 pellet fireplace, H. outside air locations & considerations – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 43

Advertising
background image

R

December 6, 2011

7051-158B

Page 43

EDGE 60 Pellet Fireplace

Outlet placed

higher than 3 ft

below the

termination cap

Attic space

Garage or

combustible

liquids storage

Outlet blocked by

snow, leaves, etc.

YES

NO

NO

NO

NO

Clear area

outside

house or in

“ventilated”

crawl space

Fireplace

Figure 42.2 - Outside Combustion Air Placement

Figure 42.1 - Outside Air Inlet Locations

H. Outside Air Locations & Considerations

Outside Air

1-3/4 in.

(44mm)

4-7/8 in.

(124mm)

C

L

C

L

C

L

C

L

Door

Outside Air

1-3/4 in.

(44mm)

4-7/8 in.

(125mm)

C

L

C

L

Door

9-1/4 in.

(235mm)

4-7/8 in.

(24mm)

Rear Vent

Outside Air

C

L

C

L

Left Rear Corner

Right Rear Corner

Rear of Fireplace

NOTE: The fi replace ships from the factory with the left and right outside
air covers installed. Once the location for the outside air inlet has been
choosen, install the outside air covers over the two unused air inlets.