Caution, Attention, Edge 60 pellet fireplace – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 2

Advertising
background image

Page 2

7051-158B

December 6, 2011

R

EDGE 60 Pellet Fireplace

Hearth & Home Technologies welcomes you to our tradition of
excellence! In choosing a Quadra-Fire appliance, you have
our assurance of commitment to quality, durability, and perfor-
mance.

This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we make
products that will satisfy your needs. Our Research and Devel-
opment facility then employs the world’s most advanced tech-
nology to achieve the optimum operation of our stoves, inserts

and fi replaces. And yet we are old-fashioned when it comes to
craftsmanship. Each unit is meticulously fabricated and surfaces
are hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality control
inspection.

We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance.

Thank you for choosing Quadra-Fire.

LOCATION OF CLEARANCE TO COMBUSTIBLES LABEL: Left Hand Panel of Hopper (Fig. 3)

Testing Lab & Report No.

Manufacture Date

Serial Number

LOCATION OF SERIAL NUMBER LABEL: Right Inside Edge of Outer Can (Fig. 2)

Open Front. Serial Number Label located
on right side inside edge of outer can.

Slide fireplace out on the rails. Clearance
to Combustible Label located on left side of
hopper.

Figure 2 - Serial Number Label

Figure 3 - Clearance to Combustibles
Label

SAFETY LABEL / ÉTIQUETTE DE SÉCURITÉ

Listed Solid Fuel Room Heater/Pellet Type. Also suitable for Mobile Home
Installation. This appliance has been tested and listed for use in Manufactured
Homes in accordance with OAR 814-23-9000 through 814-23-909.

R

EDGE 60 PELLET FIREPLACE

PREVENT HOUSE FIRES

Install and use only in accordance with manufacturer's installation
and operating instructions. Contact local building or fire officials
about restrictions and inspection in our area.
WARNING: FOR MOBILE HOMES: Do not install appliance in a
sleeping room. An outside combustion air inlet must be provided.
The structural integrity of the mobile home floor, ceiling and walls
must be maintained.
Refer to manufacturer's instructions and local codes for
precautions required for passing chimney through a combustible
wall or ceiling. Inspect and clean vent system frequently in
accordance with manufacturer's instructions.
Areas of the fireplace incorporating warm or cold air ducts shall be
enclosed according to the manufacturer’s installation instructions.
Components required for all installations: Outside Air Kit, Part

Number OAK-3.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER
APPLIANCE.
Use a 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system.
CAUTION: Combustion air openings are not to be obstructed.
CAUTION: It is necessary that this fireplace have air for proper
operation. Please refer to the owners mannual for possible
consequences of improper ventilation.

Tested to: ASTM E1509-04, ULC S628-93,
ULC/ORD-C1482-M1990 Room Heating Pellet Burning Type, (UM)
84-HUD FOR USE ONLY WITH PELLETIZED WOOD. SEE OWNER’S
MANUAL FOR OTHER FUEL OPTIONS.

OMNI-Test Laboratories, Inc. has determined that this appliance

complies with Canadian Standards Association (CSA) B415.1

and Title 40 of the U.S. Code of Federal Regulations, Part 60,

SubPart AAA.OMNI-Test Laboratories Accrediations: The

Standards Council of Canada, the American National Standards

Institute, and the U.S. Environmental Protection Agency.

Input Rating: 52,000 BTU/HR.
Electrical Rating: 115 VAC, 60 Hz, Start 5 Amps, Run 1.25 AMPS.
DANGER: Risk of Electric Shock. Disconnect Power Before
Servicing Unit.
Replace glass only with 5mm ceramic available from your dealer.
To start, set thermostat above room temperature, the stove will light
automatically. To shutdown, set thermostat to below room
temperature.

For further instruction refer to owner's manual.

Keep viewing & ash removal doors tightly closed during operation.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

7051-148C

NE PAS ENLEVER L'ÉTIQUETTE

CAUTION

:

ATTENTION:

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE

AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate

this unit only with the fuel hopper lid closed. Failure to do so may result in emissions of products of

combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do not

overfill hopper.

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE

L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet

appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions,

en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.

A Surfaces Mur de arrières

0 in (0mm)

B Surfaces Mur de côté

0 in. (0mm)

C Surfaces supérieurs à la boutisse

0 in. (0mm)

D Du conduits des combustibles

*

E Protection du plancer dessus cheminéel: Ne pas requis

A Standoff to Back Wall

0 in. (0mm)

B Standoff to Side Walls

0 in (0mm)

C Top Standoff to Header

0 in (0mm)

D Vent Pipe to Combustible

*

E Floor Protection under Fireplace

None Required

PRÉVENTION DES FEUX DE MAISON

Installez et utilisez en accord avec les instructions d'installation et d'opération du
fabricant. Contactez le bureau de la construction ou le bureau des incendies au
sujet des restrictions et des inspections d'installation dans votre voisinage. Ne pas
obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles: Ne pas installer dans une chambre à coucher.
Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué
lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et
des murs de la maison mobile doit être maintenue intacte.
Référez vous aux instructions du fabricant et des codes locaux pour les précautions
requises pour passer une cheminée à travers un mur ou un plafond combustibles,
et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment.
Domaines de la cheminée incorporant les gaines d'air chaud ou froid doivent être
enfermés en conformité avec les instructions d'installation du fabricant.
Les composants requis pour tout l'installations. Assemblage d'air extérieur, Numéro de
Pièce OAK-3.
Ne pas connecter cet appareil à une cheminée servant un autre appareil.
Utilitsez le système de ventilation de 3 or 4 inch (76-102mm) de diametre de type “L” ou “PL”.
ATTENTION: ouvertures d'air de combustion ne doivent pas être obstruées.
ATTENTION: Il est nécessaire que ce foyer ont l'air d'un bon fonctionnement. S'il vous plaît
se référer à des propriétaires mannual pour les conséquences possibles d'une mauvaise
ventilation.

Testé à: ASTM #1509-04, ULC S628-93, ULC/ORD-C1482-M1990 Room
Heating. Pellet Burning Type, UM) 84-HUD POUR USAGE AVEC LES
BOULETTES DE BOIS. VOIR LE MANUAL DU PROPRIÉTAIRE POUR
D’AUTRES OPTIONS DE CARBURANT.

OMNI-Test Laboratories, Inc. a déterminé que cet appareil se conforme avec la

norme de l’Association Canadienne de normalisation (CSA) B415.1 ainsi que

le Titre 40 du Code Fédéral de Régulations des États-Unis, partie 60,

sous-partie AAA. Accréditations OMNI-Test Laboratories : Le Conseil

Canadien des Normes (CCN/SCC), l’Institue des Standards Nationaux

Américain (ANSI) et l’Agence de Protection Environnemental (EPA

).

Puissance de Rendement: 52,000 BTU/HR
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps,
DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise
de contact avant le service. Remplacez la vitre seulement avec une vitre céramique de
5 mm disponible chez votre fournisseur.
Pour allumer, monter la température du thermostat au dessus de la température de la
pièce, le poêle s'allumera automatiquement. Pour éteindre, descendre la température
du thermostat en dessous de la température de la pièce. Pour des instructions
supplémentaires, référez vous au manuel du propriétaire. Gardez la porte d'ouverture
et la porte des cendres fermées hermétiquement durant l'opération.

Appareil de chauffage de combustible solide/de type de boulettes. Accepté dans
l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage
dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.

DO NOT REMOVE THIS LABEL

F Floor Protection Hearth Extension From Door Opening 6 in (152mm)
G Floor Protection to the Side of Door Opening

6 in (152mm)

* Use Pipe Manufacturer’s Listed Clearances, 1 inch (25mm) Minimum

*Voir le fabricant pour les espaces libres des conduits enregistré, 1 inch (25mm) minimum

F Portection du plancer agrandissement du foyer à ouverture du port: 6 in (152mm)
G Portection du plancer de côté à ouverture du port:

6 in (152mm)

C

A

B

A

F

G

ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES

ALL MATERIAL USED FOR FLOOR PROTECTION MUST BE NON-COMBUSTIBLE

O - T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

JAN FEB MAR APR MAY JUNE

7051-159C

Fabriqué par

:

1445 Highway North, Colville, WA 99114

Manufactured by:

www.quadrafire.com

R

EDGE 60 PELLET

FIREPLACE

Report

/

Rapport

#061-F-75-6.2

007007

O - T L

Tested and

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

JULY AUG SEP OCT NOV DEC

2012

2013

2014

Made in U.S.A.

of US and

imported parts.

Fabriqué aux

États-Unis-d’Amérique par des

pièces d’origine américaine et

pièces importées.

Advertising