Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 54

Advertising
background image

Page 54

7051-158B

December 6, 2011

R

EDGE 60 Pellet Fireplace

When describing the location of a component,
it is always AS YOU FACE THE FRONT OF
THE APPLIANCE.

B. Component Functions

1. Auto-Clean Motor

Location: Behind and under the fi repot on the left side, inside
the convection air chamber

Function: It automatically opens and closes the fi repot fl oor
so ashes can fall into the ash pan.

2. Auto-Clean Switch

Location: On top of the auto-clean motor

Function: Communicates to the control board when the fi repot
fl oor is open and when the auto-clean system has completed
its cycle and is back in the home (closed) position.

3. 12 Volt Battery Back-Up Cable (Optional Accessory)

Location: Plugs into the appliance at the lower left front of
the appliance.

Function: An icon will display on the wall control when the
appliance has lost main power and is running on battery
back-up.

4. Combustion (Exhaust) Blower

Location: Mounted in the bottom right rear of appliance.

Function: Pulls the exhaust from the appliance and pushs it
out through the venting system.

5. Control Board

Location: Lower left side of appliance.

Function: Controls the functioning of the appliance and
communicates with the wall control. The control board can
only be opened by an authorized dealer.

6. Convection Blower

Location: Mounted at the bottom left rear of the appliance

Function: Pushes heated air through the heat exchange
system into the room.

7. Door Switch

Location: Mounted on the right side of the fi rebox behind
the door handle

Function: Senses when the door is open and will display an
icon on the wall control and will turn off the auto-clean system
and feed motor for safety.

8. Feed System

Location: On the right side of the appliance and can be
removed as an entire assembly. The assembly includes
the feed motor, mounting bracket, bearing and feed spring
(auger).

Function: The hollow feed spring (auger) pulls pellets up the
feed tube from the hopper area and drops them down the
feed chute into the fi repot

9. Firepot

Location: Inside fi rebox and is made of high quality ductile
iron.

Function: The fl oor of the fi repot automatically opens for
cleaning and is operated by the auto-clean fi repot system.
The fl oor needs to return to a completely closed position or
the appliance will not operate properly.

10. Fuses

Location: One

AC fuse and one DC fuse is located on the

inside of the control board and a third fuse is located in the
power supply. Figures 54.1 & 54.2 on page 54.

Function:

The AC fuse operates the igniter and the DC

fuse operates all of the other components.

The third fuse

protects the components in the power supply. A fuse will
blow should a short occur and shut off power to the appli-
ance. The fuses can only be replaced by an authorized
dealer.

11. Heat Exchanger

Location: B

ehind the baffl e.

Remove the cast iron baffl e

to access the heat exchanger.

Function: T

ransfers heat from the exhaust system into the

convection air chamber.

12. Hopper Lid Switch

Location: Lower

front right side of appliance on the power

switch cover.

Function: S

enses whether the hopper lid is open and dis-

plays an icon on the wall control and will turn off the feed
motor.

13. Interlock Switch

Location: Lower

front right side of appliance behind power

switch.

Function: Causes the auger to stop functioning and will be
opened when the appliances slides are extended.

14. Igniter (Heating Element)

Location: M

ounted on the base of the fi repot.

Function: Combustion air travels over the red hot igniter
creating super heated air that ignites the pellets or other
fuels.

15. Power Receptacle

Location: L

ower rear of the appliance

Function: Check the wall receptacle for 120 volt, 60 Hz
(standard current). Make sure the outlet is grounded and
has the correct polarity.

Advertising