EDGE 60 Pellet Fireplace

Figure 54.1 - Power Supply

Figure 54.2 - Control Board

120V AC in

120V AC out to
Control Board

15V DC out to
Control Board

Fuse 15A 250V

(need to remove

cover)

Heat sinks are taped to cover for
shipping. Slowly lift cover and cut the
tape holding them in place and then
you can remove the cover.

#

Description

#

Description

#

Description

1

Combustion Blower

7

Thermostat Wall Control

12

Igniter

2

Auto-Clean System

8

Combustion Blower (feedback)

13

AC Power In for Igniter

3

Feed/Auger Motors

9

Firepot Thermocouple

14

Convection Blower Power

4

Hopper/Door Switches

10

Drop Tube Thermocouple

15

Overheat Sensor (Snap Disc)

5

Auger/Auto Clean/Vacuum Switches

n/a

Not Used

16

DC Power In from Power Supply

6

Low Fuel

11

Convection Blower (feedback)

17

12 Volt Battery Back-up

17

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

n/a

Fuse 15A 120V,
under the cover

Fuse 15A 120V,
under the cover

18. Overheat Sensor (Snap Disc)

Location: M

ounted on the back of the drop tube in the center

of the appliance and has a reset button. Remove the right side
panel to access.

Function: If the fi re tries to burn back into the feed system or
push exhaust up the feed tube, this sensor will shut the appli-
ance down, however the wall control will still display messages.
This sensor must be manually re-set. Disconnect power before
resetting.

19. Thermocouple - Firepot

Location: O

n top of the fi repot inside the thermocouple cover

(ceramic protection tube)

Function: Sends a millivolt signal to the control board telling the
control board there is a fi re in the fi repot.

20. Thermocouple - Drop Tube

Location: B

ottom of the drop tube on the right side and

attached with a wing nut

Function: Turns the convection blower on and off, varies
the speed of the convection blower and will shut down
appliance if internal heat exceeds set temperature.

21. Vacuum Switch

Location: R

ight side of the appliance under the feed

motor behind right side panel and connects to the drop
tube with a hose

Function: Turns the feed system on when vacuum is
present in the fi rebox. The vacuum switch is a safety
device to shut off the feed motor if the exhaust or the
heat exchanger system is dirty, plugged or if the fi rebox
door is open.

22. Wall Control, Thermostat

Location: Interior wall of the home

Function:

The appliance is designed to run on a custom

designed 3.3 volt DC thermostat wall control. It will not
operate on any other wall control. Refer to the instruc-
tions supplied with the appliance, located in the compo-
nent pack.

23. Wiring Schematic for Power Supply

See Figure 54.1 below.

24. Wiring Schematic for Control Board

See Figure 54.2 below.

Control Board Schematic

16. Power Supply

Location: A

t the rear of the appliance

Function: Converts 120 volt AC current to 15 volt DC current to
power the appliance.

17. Power Switch

Location: Lower front right side of appliance

Function: Turns the power on and off to the appliance