C. convection blower replacement, D. baffl e removal & replacement – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 51

Advertising
background image

R

December 6, 2011

7051-158B

Page 51

EDGE 60 Pellet Fireplace

C. Convection Blower Replacement

1. Follow the proper shut down procedures as outlined on

page 14, Section 3.A.

Figure 50.1

D. Baffl e Removal & Replacement

1. Follow the proper shut down procedures as outlined

on page 14, Section 3.A.

2. Open front and open fi rebox door.

3. The baffl e is located at the top inside of fi rebox.

4. To remove the baffl e:

a. Place a fl at head screwdriver into the slot of the

latches located in the upper corners. Figure
50.3.

b. Push down and the bottom of the latch will fall

forward off of the post.

c. Lift the baffl e up and then out toward you.

5. To replace the baffl e:

a. Place the 2 locating ears behind the bottom edge.

b. Tilt the baffl e up and into place.

The baffl e must be centered in the fi rebox before
latching it in place
.

c. If it is not centered the latch is trapped between

the baffl e and side of the fi rebox instead of latch-
ing properly.

d. The bottom of the latches will fi t over the posts.

e. Push the top of the latch forward to lock latch into

place.

Baffle

Latches

Insert flat head screw driver into “V”
section and push down and the bottom
of the latch will fall forward off of post

Locating ears - 1 on
each side. Fit behind
bottom edge.

Figure 50.3

WARNING! Risk of Injury! Cast iron is a very heavy
material.
The baffl e is made of cast iron and therefore is
heavy and awkward at times to maneuver. Clear and prepare
your work area before you begin.

2. Remove the 2 bolts from the bottom left and right side

of the fi replace and slide the fi replace out.

3. Locate the convection blower on the bottom left rear of

the fi replace. Reach behind the blower and release the
latch by pushing the top of the latch towards the blower.
Figure 50.1.

4. Rock the top of the blower slightly and lift up and out.

The blower will pass around the control board and out
the side of the fi replace.

5. Disconnect the wire harness from the bottom of the

blower by depressing the tabs on the sides of the con-
nector and then pulling to remove.

6. Re-connect wire harness to the new replacement

blower. Install the blower by placing the bottom fl ange
into the opening fi rst then rotate blower up into posi-
tion.

7. When the blower is properly positioned the latch will engage

the notch to hold the blower in place. Figure 50.2.