K. battery back-up system (optional) – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 12

Advertising
background image

Page 12

7051-158B

December 6, 2011

R

EDGE 60 Pellet Fireplace

J. Fire Characteristics and Flame Height

(Feed Rate) Adjustment

A properly adjusted fi re will have an active fl ame pattern
and the fl ame will rise and fall somewhat. This is normal.

• On HIGH setting, the fl ame will extend approximately

203mm out of the fi repot. If it is not 203mm tall, in-
crease the fl ame height.

• On MEDIUM or LOW setting the fl ame will be shorter.

• Reduce the fl ame height if the fi re has tall fl ames with

black tails and seems somewhat lazy. This may also
indicate that the fi repot and/or heat exchanger needs
to be cleaned. Refer to Section 3 for Maintenance and
Cleaning Instructions.

Adjusting the Flame Height (Feed Rate)
• Set your appliance to “MANUAL” mode on the wall

control.

• Set the heat output level to HIGH.

• Adjust the fl ame height using the “FLAME HEIGHT

ADJUST” screen on the wall control. Figure 12.1.

Figure 12.1

The appliance has been designed to operate on an optional
battery back-up system.

If you have frequent power outages in your region, hook
the appliance up to a 12 volt battery and it will automatically
switch to battery power in the event of a power failure. The
12 volt power cord, sold as a separate accessory, does not
charge the battery.

13 Volts

12 Volts

11 Volts

Battery

Below

10 Volts

Figure 12.3

Operating on Battery Back-Up

A battery icon appears on your wall control to let you

know you are now operating on battery power. Figure
12.3

• The fi re must be manually lit as the appliance will no

longer automatically light. Follow the instructions in the
Wall Control Manual.

Use only approved fi re starting gel to start the fi re.

• The high burn rate is no longer available on battery

back-up.

• E

ach level drops down one level, i.e

the high burn be-

comes medium-high burn and so on.

• If the battery charge falls below 10 volt it can no longer

sustain the appliance operation and the appliance will
shut down. You must disconnect and reconnect the bat-
tery to start it up again.

Recommended Battery

• 12 volt deep cycle battery, (i.e., marine or RV type).

A 12 volt battery cable is available through your local

dealer.

Instructions to Hook Up to Battery Back-Up

Open Front to expose battery plug on bottom left side of
fi replace. Plug in the battery. Figure 12.2. Be sure the bolts
securing the unit in place are installed and secured.

Firebox Door

Ash Door

Left Side

Battery Plug In

Figure 12.2

WARNING! Risk of Injury!

• Do not operate in the battery back-up mode with the

appliance pulled out on the slide rails.

• Blowers may continue to run and would be exposed to

human contact.

CAUTION!

• Hook up to battery terminals BEFORE you plug battery

into appliance.

• Damage to internal electronic components may occur.

K. Battery Back-up System (Optional)

Advertising