Edge 60 pellet fireplace l. through the wall, Straight out, 45 degree – Quadra-Fire EDGE 60 ZERO CLEARANCE PELLET FIREPLACE 7051-158B User Manual

Page 46

Advertising
background image

Page 46

7051-158B

December 6, 2011

R

EDGE 60 Pellet Fireplace

L. Through the Wall

Figure 45.1

12 in.

(305mm)
Minimum

W all
Thimble

Horizontal
T ermination
Cap

6 in.

(152mm)
Minimum

From Glass

Non-combustible
Hearth Extension

0 in. (0mm) to Standoff

Straight Out

Wall
Thimble

Illustration shows venting going in both directions.
Choose which one is best for your installation.

1-1/6 in.( 27mm)

Minimum

1-16 in.

(27mm)

Minimum

12 in. (305mm)

Minimum

12 in. (305mm)

Minimum

Figure 45.2

45 Degree

Horizontal termination cap must be a minimum of 12 inches
(305mm) from the wall. Approved for mobile home installations.
Must use 3 or 4 inch (76mm-102mm) “L” or “PL” Listed pellet
venting and a Quadra-Fire Outside Air Kit in ALL installations.

NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365

NOTICE! See Section 8 “Avoiding Smoke and Odors” to minimize soot
damage to exterior walls of the house and to prevent re-entry of soot or ash
into the house for horizontal vent confi guration