12 mdio user phy select register 0 (userphysel0), Section 4.12 – Texas Instruments TMS320DM36X User Manual

Page 80

Advertising
background image

MDIO Registers

www.ti.com

4.12 MDIO User PHY Select Register 0 (USERPHYSEL0)

The MDIO user PHY select register 0 (USERPHYSEL0) is shown in

Figure 37

and described in

Table 34

.

Figure 37. MDIO User PHY Select Register 0 (USERPHYSEL0)

31

16

Reserved

R-0

15

8

7

6

5

4

0

Reserved

LINKSEL

LINKINTENB

Rsvd

PHYADRMON

R-0

R/W-0

R/W-0

R-0

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 34. MDIO User PHY Select Register 0 (USERPHYSEL0) Field Descriptions

Bit

Field

Value

Description

31-8

Reserved

0

Reserved

7

LINKSEL

Link status determination select bit. Default value is 0, which implies that the link status is
determined by the MDIO state machine. This is the only option supported on this device.

0

The link status is determined by the MDIO state machine.

1

Not supported.

6

LINKINTENB

Link change interrupt enable. Set to 1 to enable link change status interrupts for PHY address
specified in PHYADRMON. Link change interrupts are disabled if this bit is set to 0.

0

Link change interrupts are disabled.

1

Link change status interrupts for PHY address specified in PHYADDRMON bits are enabled.

5

Reserved

0

Reserved

4-0

PHYADRMON

0-1Fh

PHY address whose link status is to be monitored.

80

Ethernet Media Access Controller (EMAC)/Management Data Input/Output

SPRUFI5B – March 2009 – Revised December 2010

(MDIO)

Submit Documentation Feedback

© 2009–2010, Texas Instruments Incorporated

Advertising