• The maximum pipe length of this air conditioner is

66 ft (

20m

)

. When the pipe length exceeds

50 ft (

15m

)

, the

additional

charging of refrigerant,

0.22 oz/ft (

20g per 1m

)

for the part of pipe exceeded

50 ft (

15m

)

is required.

Max.

:

66ft (

20m

)

Min. :

6.6ft (

2m

)

Chargeless :

50ft (

15m

)

Charge :

0.22oz/ft (20g/m)

(

51 to 66ft

)

Deoxidized copper pipe

NOTE:

Gas leak check position

Refrigerant

flow

(Cooling)

Refrigerant

flow

(Heating)

INDOOR UNIT

T1

Temp. measurement

Indoor heat

exchanger

Cross flow fan

Sectional shape
of heat insulator

Allowable height

difference:

33ft (

10m

)

Allowable pipe length

P

Pressure measurement
Gauge attaching port
Vacuum pump connecting port

Strainer

Pulse Modulating valve
at liquid side

TD

4-way valve

Compressor

DA150A1F-20F1

Propeller fan

Refrigerant amount:

3.09 lbs (

1.40kg

)

OUTDOOR UNIT

TC

TA

Outdoor heat
exchanger

Split capillary
2-dia. 1.2 × 80

TE

Muffler

Muffler

Accumulater tank

Deoxidized copper pipe

Outer dia. : 1/4 in. (6.35mm)

Thickness : 1/32 in (0.8mm)

TS

TO

Distributor

Outer dia. : 1/2 in. (12.7mm)

Thickness : 1/32 in (0.8mm)

Muffler

High pressure SW

Fusible Plug

[Max. 0.22 lbs (100g)].

FILE NO. SVM-10020