2. primary judgment, 3. judgment by flashing led of indoor unit – Toshiba CARRIER RAS-15LKV-UL User Manual

Page 69

Advertising
background image

– 69 –

11-2. Primary Judgment

To diagnose the troubles, use the following methods.
1) Judgment by flashing LED of indoor unit
2) Self-diagnosis by service check remote controller
3) Judgment of trouble by every symptom

Firstly use the method 1) for diagnosis. Then, use the method 2) or 3) to diagnose the details of troubles.

11-3. Judgment by Flashing LED of Indoor Unit

While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the

contents of self-diagnosis are displayed with block on the indoor unit indication section.

Table 11-3-1

NOTES :
1. Some check code will flash display of the indoor unit, when the air conditioner operates with some limitation.
2. Some check code will flash display of the indoor unit and stop operation of the air conditioner.
3. When item B and C or item B and apart of item E occur concurrently, priority is given to the block of item B.

OPERATION (Green)

Flashing display (1 Hz)

OPERATION (Green)

TIMER (Yellow)

FILTER (Orange)

Flashing display (5 Hz)

OPERATION (Green)

FILTER (Orange)

Flashing display (5 Hz)

OPERATION (Green)

TIMER (Yellow)

Flashing display (5 Hz)

OPERATION (Green)

Flashing display (5 Hz)

Protective circuit operation for indoor P.C. board

Protective circuit operation for connecting cable

and serial signal system

Protective circuit operation for outdoor P.C. board

Protective circuit operation for others

(including compressor)

Indoor indication

lamp flashes.

Which lamp

does flash?

Item

A

B

C

D

E

Check

code

Block display

Description for self-diagnosis

FILE NO. SVM-10020

When turn ON power supply.

Power supply ON after failure or OFF.

This flashing display is not air conditioner failure.

4. The check codes can be confirmed on the remote controller for servicing.