Toshiba CARRIER RAS-15LKV-UL User Manual

Page 96

Advertising
background image

– 96 –

No.

Part name

Cross flow fan

Procedures

<Caution at reassembling>

1) To incorporate the fan motor incorporate the

motor into the position in the following figure,
and then install the fan motor.

Remarks

• Install the cross flow fan so that the right

end of the 1st joint from the right of the
cross flow fan is set keeping 5.0 mm from
closed wall of the main unit.

• Holding the set screw, install the cross flow

fan so that flat area on shaft of the fan motor
comes to the mounting hole of the set screw.

q

FILE NO. SVM-10020

• Perform positioning of the fan motor as

follows:

• When assembling the fan motor, the fan

motor must be installed in such a way that
the fan motor leads will be taken out is
positioned at the bottom front.

• After assembling the two hooking claws of

the motor band (right) into the main body,
position the fan motor, insert it, and then
secure the motor band (right) using the two
fixing screws.

Advertising