11-5. Judgement of Trouble by Every Symptom

11-5-1. Indoor unit (Including remote controller)

(1) Indoor unit is not operated.

(2) Operation is not turned on though Indoor P.C. board is replaced

<Confirmation procedure>

NO

Turn off power supply once, and
5 second later, turn it on again.

Is OPERATION indicator flashing?

Is it possible to turn on

A/C by pushing

[

] button

on remote controller?

Is voltage

(DC5V, 12V and 15V)

indicated on rear of

indoor control

board nor mal?

Does transmission mark

on remote controller flash

normally,and is its signal

transmitted properly?

Does fan

motor connector

between CN10 1 –

3 short-circuit?

Item by symptoms

Operation

Check Item

Considerable principle cause

Measures

Remote controller is defective.

Refer to (5) “Troubleshooting
for remote controller”.

Unit operates normally.

Replace main
P.C. board

Replace fan
motor.

Is fuse (F01)

of indoor control

board blown?

Microcomputer

is defective.

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

Point remote to digital

camera. Can see infrared

ray at sending LED

when push [ ] button?

Replace remote control

Does connection

between PC Board

and reciver PCB

Reconnect housing

on camera monitor

YES

YES

are connect properly?

YES

NO

NO

To item of
“Indoor unit is not operated”.

Turn on power supply.

Does OPERATION indicator flash?

Is wired correctly to white and

black lead wires of terminal block?

NO

NO

YES

Correct wiring

76