Item

Operation flow and applicable data, etc.

Description

42

FILE NO. SVM-10020

14. Remote-A or B

selection

1. Purpose

This operation is to operate only one
indoor unit using one remote controller.

2. Description

When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents the
remote controller signal from being
received simultaneously by both units,
thus preventing both units from operating.

3. Operation

The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)

Setting the remote controller

To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.

Remote Control B Setup.

1) Press RESET button on the indoor unit to turn

2) Point the remote control at the indoor unit.

3) Push and hold CHK

button on the Remote

Control by the tip of the pencil. "00" will be shown

the air conditioner ON.

shown on the display.

4) Press MODE

during pushing CHK

. "B" will

show on the display and "00" will disappear and

the air conditioner will turn OFF. The Remote

Control B is memorized.

Note : 1. Repeat above step to reset Remote Control

to be A.

2. Remote Control A has not "A" display.

3. Default setting of Remote Control from

factory is A.

PRESET

FAN

“B” Display

“00” Display

PCB NO : MCC-5045

PCB NO : WP-020

PCB NO : MCC-5046

J201