13. Self-Cleaning

Operation flow and applicable data, etc.

1. Purpose

The Self-Cleaning operation is to minimize the
growth of mold, bacteria etc. by running
the fan and drying so as to keep the
inside of the air conditioner clean.

Self-Cleaning operation

When the cooling or dry operation shuts
down, the unit automatically starts the Self-
Cleaning operation which is then performed
for the specified period based on duration
of the operation which was performed
prior to the shutdown, after which the
Self-Cleaning operation stops.
(The Self-Cleaning operation is not
performed after a heating operation.)

2. Operation

1) When the stop signal from the remote

controller or timer-off function is received,
only the timer indicator light.

2) The period of the Self-Cleaning operation

is determined by the duration of the
operation performed prior to the
reception of the stop code.

3) After the Self-Cleaning operation has

been performed for the specified period,
the unit stops operating.

Unit now performing cooling or dry operation

Press “STOP” button

Only timer indicator lights, and Self Cleaning operation starts

Time set now elapses

Operation stops

function

• During Self-Cleaning operations: The louver opens

slightly. The indoor fan operates continuously at

a speed of 500 rpm.

Cooling: Auto (cooling) Dry

Heating: Auto (heating)
Auto (fan only)
Shutdown

Operation time

Up to 10 minutes

No Self-Cleaning operation

performed (0 minutes)

10 minutes

30 mins.

or longer

No Self-Cleaning operation performed

• To stop an ongoing Self-Cleaning operation at any time

Press the start/stop button on the remote controller twice during the Self-Cleaning

operation. (After pressing the button for the first time, press it for the

Self-Cleaning operation times

second time without delay (within 10 minutes).)

Description

Self-Cleaning operation time

FILE NO. SVM-10020