Caution, Information – Toshiba CARRIER RAS-15LKV-UL User Manual

Page 59

Advertising
background image

– 59 –

CAUTION

• Bind the auxiliary pipes (two) and connecting

cable with facing tape tightly.

In case of leftward piping and rear-leftward
piping, bind the auxiliary pipes (two) only with
facing tape.

Fig. 10-3-18

• Carefully arrange the pipes so that none of the

pipes stick out of the rear plate of the indoor unit.

• Carefully connect the auxiliary pipes and

connecting pipes to each other and cut off the
insulating tape wound on the connecting pipe
to avoid double-taping at the joint, moreover,
seal the joint with the vinyl tape, etc.

• Since condensation can result in machine

performance trouble, be sure to insulate both
connecting pipes. (Use polyethylene foam as
insulating material.)

• When bending a pipe, be careful not to crush it.

10-3-6. Indoor Unit Installation

1. Pass the pipe through the hole in the wall, and

hook the indoor unit on the installation plate at
the upper hooks.

2. Swing the indoor unit to right and left to confirm

that it is firmly hooked on the installation plate.

3. While pressing the indoor unit onto the wall, hook

it at the lower part on the installation plate.
Pull the indoor unit toward you to confirm that it is
firmly hooked on the installation plate.

Installation
plate

Indoor unit

Connecting
cable

Auxiliary pipes

Fig. 10-3-19

• For detaching the indoor unit from the installation

plate pull the indoor unit toward you while pushing
the bottom up at the specified places.

Fig. 10-3-20

Push

Push

Push (unhook)

1 Installation

plate

Hook here

2

Hook

1

FILE NO. SVM-10020

Screw

Screw

9

Information

The lower part of indoor unit may float, due to the

condition of piping and you cannot fix it to the

installation plate. In that case, use the

9 screws

trovided to fix the unit and the installation plate.

9

CAUTION

10-3-7. Drainage

1. Run the drain hose at a downward sloped angle.

NOTE :

• Hole should be made at a slight downward slant

on the outdoor side.

50 mm

or more

Do not rise
the drain hose.

Do not form the drain hose
into the waved shape.

Do not put the
drain hose end
into water.

Do not put the drain
hose end in the
drainage ditch.

Shield pipe

Extension drain hose

Inside the room

Drain hose

Fig. 10-3-19

2. Put water in the drain pan and make sure that

the water is being drained outside.

3. When connecting extension drain hose, insulate

the connection part of extension drain hose with
shield pipe.

Fig.

10-3-21

Advertising