Toshiba CARRIER RAS-15LKV-UL User Manual

Page 38

Advertising
background image

– 38 –

Item

10. Temporary

operation

Operation flow and applicable data, etc.

Pressing [RESET] button starts the temporary opera-

tion of [AUTO] operation. When keeping [RESET]

button pressed for 10 seconds or more, the temporary

[COOL] operation is performed.

Description

1) When pressing [RESET] button, the

temporary [AUTO] operation starts.

2) When keeping [RESET] button pressed

for 3 seconds or more, Pi, Pi, Pi sound is

heard and [AUTO RESTART] control is

changed.

3) When keeping [RESET] button pressed

for 10 seconds or more, “Pi” sound is

heard and the temporary [COOL]

operation starts.

4) If the filter lamp goes on, press [RESET]

button to go off the filter lamp, and then

press [RESET] button again.

5) To stop the temporary operation, press

the button again.

Filter lamp ON

Press RESET button.

Did you press [RESET] button

for 3 seconds or more?

Did you press [RESET] button

for 10 seconds or more?

Set or Reset [AUTO RESTART]

YES

YES

NO

NO

NO

YES

Temporary [AUTO] operation

Temporary [COOL] Operation

11. Discharge temperature control

1. Purpose

This function detects error on the

refrigerating cycle or error on the com-

pressor, and performs protective control.

2. Operation

• Control of the compressor speed

The speed control is performed as

described in the left table based upon

the discharge temperature.

Td value

243°F (117°C)

233°F (112°C)

226°F (108°C)

221°F (105°C)

208°F (98°C)

Control operation

Judges as an error and stops the compressor.
Reduce the compressor speed.
Reduce slowly compressor speed.
Keeps the compressor speed.
If the operation is performed with lower speed than one

commanded by the serial signal, speed is slowly raised

up to the commanded speed.

Operates with speed commanded by the serial signal.

FILE NO. SVM-10020

Advertising