NOTE :

• The maximum pipe length of this air conditioner is 15 m. The additional charging of refrigerant is unneces-

sary because this air conditioner is designed with charge-less specification.

Deoxidized copper pipe

Outer dia. : 9,52mm
Thickness : 0,8mm

NOTE :

Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

INDOOR UNIT

T1

Temp. measurement

Indoor heat

exchanger

Cross flow fan

Deoxidized copper pipe
Outer dia. : 6,35mm
Thickness : 0,8mm

Sectional shape
of heat insulator

Allo

w

a

b

le height

diff

erence :

10m

Allo

w

a

b

le pipe length

Max. : 15m

P

Pressure measurement
Gauge attaching port
Vacuum pump connecting port

Strainer

Pulse modulating
valve at liquid side
(SEV15RC2)

Ø1,5 x 200

Ø1,5 x 200

TD

4-way valve
(CHV-0213)

Compressor
DA91A1F-44F

TS

T2

Outdoor heat

exchanger

Split capillary

Temp. measurement

Propeller fan

Refrigerant amount : 0,8kg

OUTDOOR UNIT

Muffler

Muffler

TE

6. REFRIGERANT CYCLE DIAGRAM

6-1. Refrigerant Cycle Diagram

RAS-10YKV-E/RAS-10YAV-E
RAS-13YKV-E/RAS-13YAV-E