Toshiba RAS-10YKV-E User Manual

Page 62

Advertising
background image

– 62 –

Procedure

1. Detachment
1) Stop operation of the air conditioner, and remove

the power plug of the indoor unit from plug
socket.

2) Remove the valve cover. (ST1TØ4 x 10

l

1 pc.)

• After removing screw, remove the valve cover

pulling it downward.

3) Remove wiring cover (ST1TØ4 x 10

l

2 pcs.),

and then remove connecting cable.

4) Remove the upper cabinet.

(ST1TØ4 x 10

l

2 pcs.)

• After removing screws, remove the upper

cabinet pulling it upward.

2. Attachment
1) Attach the upper cabinet.

(ST1TØ4 x 10

l

2 pcs.)

• Hook the rear side of the upper cabinet to claw

of the rear cabinet, and then put it on the front
cabinet.

2) Perform cabling of connecting cable, and attach

the wiring cover.
• Insert the upper part into the upper cabinet,

insert claw which has been hooked to the
lower part into the square hole, and then fix it
with screw. (ST1TØ4 x 10

l

1 pc.)

3) Attach the valve cover. (ST1TØ4 x 10

l

1 pc.)

• Insert the upper part to the upper cabinet, set

hook claw of the valve cover to square holes
(at three positions) of the main unit, and attach
it pushing upward.

1. Detachment
1) Perform work of item 1 of

Q

.

2) Remove screws (ST1TØ4 x 10

l

1 pc.) of the

front cabinet and inverter cover and screws
(ST1TØ4 x 10

l

3 pcs.) of the front cabinet and

lower part.
• The left side of the front is made to insert to

the rear cabinet, so remove it pulling upward.

2. Attachment
1) Insert claw at the left side of the front into the

rear cabinet.

2) Hook the lower part at the right side of the front

to concave part of the bottom plate. Insert claw
of the rear cabinet into square hole of the front
cabinet.

3) Attach the removed screws to the original

positions.

No.

Part name

Q

Common
procedure

R

Front cabinet

Remarks

Upper cabinet

Wiring
cover

Valve
cover

Square hole

Claw

Concave section

11-3. Outdoor Unit

Advertising