Toshiba RAS-10YKV-E User Manual

Page 65

Advertising
background image

– 65 –

No.

Part name

V

Fan motor

W

Compressor

X

Reactor

Remarks

Procedure

1) Perform work of item 1 of

Q

and

R

.

2) Remove the flange nut fixing the fan motor and

the propeller.
• Flange nut is loosened by turning clockwise.

(To tighten the flange nut, turn counterclock-
wise.)

3) Remove the propeller fan.
4) Disconnect the connector for fan motor from the

inverter.

5) Remove the fixing screws (3 pcs.) holding by

hands so that the fan motor does not fall.

1) Perform work of item 1 of

Q

and

R

,

S

,

T

,

U

.

2) Extract refrigerant gas.
3) Remove the partition board.

(ST1TØ4 x 10

l

2 pcs.)

4) Remove the sound-insulation material.
5) Remove terminal cover of the compressor, and

disconnect lead wire of the compressor thermo.
and the compressor from the terminal.

6) Remove pipe connected to the compressor with

a burner.

7) Remove the fixing screw of the bottom plate and

heat exchanger. (ST1TØ4 x 10

l

1 pc.)

8) Remove the fixing screw of the bottom plate and

valve clamping plate. (ST1TØ4 x 10

l

2 pcs.)

9) Pull upward the refrigeration cycle.
10) Remove nut fixing the compressor to the

bottom plate.

1) Perform work of item 1 of

Q

, and

S

.

2) Remove lead wires clung in holder on the

partition board.

3) Remove screws fixing the reactor.

(ST1TØ4 x 10

l

2 pcs.)

;

;

;

;

Fan motor

Propeller fan

Flange nut

Valve
clamping
plate

Compressor
thermo.

Compressor

Partition
board

Reactor

Advertising
This manual is related to the following products: