– 57 –

No.

Part name

1

Electrolytic capacitor
(For raising pressure,
smoothing)

2

Converter module

Checking procedure

1. Turn OFF the power supply breaker.
2. Discharge all four capacitors completely.
3. Check that safety valve at the bottom of capacitor is not broken.
4. Check that vessel is not swollen or exploded.
5. Check that electrolytic liquid does not blow off.
6. Check that the normal charging characteristics are shown in

continuity test by the tester.

C12, C13, C14

500µF/400V

1. Turn OFF the power supply breaker.
2. Discharge all four capacitors completely.
3. Check that the normal rectification characteristics are shown in

continuity test by the tester.

MCC-808
Soldered
surface

Heat sink IGBT side

C12

C13

C14

C15

Case that product is good

Pointer swings once, and
returns slowly. When
performing test once again
under another polarity, the
pointer should return.

Resistance value

in good product

Diode check

IGBT check

Tester rod

+ ~ – ~

A

2

1

+

~

1

~

2

A

Mark

E

G

E

G

+

~

1

~

2

+

~

1

~

2

E

~

1

~

2

Resistance value

in good product

50k or more

(0 in trouble)

50k or more

(0 in trouble)

Tester rod

+

~

2

~

1

~

2

G

E

A