2. outdoor unit (in ver ter assemb ly ), Micro-computer block diagram – Toshiba RAS-10YKV-E User Manual

Page 22

Advertising
background image

– 22 –

7

-2.

Outdoor Unit (In

ver

ter Assemb

ly

)

RAS-10Y

A

V

-E,
RAS-13Y

A

V

-E

220–230–240 V

~ 50/60 Hz

MICRO-COMPUTER BLOCK DIAGRAM

Over current

sensor

Driver circuit

of P.M.V.

Over current

sensor

Heat exchanger

temp.sensor

Suction temp.

sensor

Outdoor air

temp. sensor

Discharge

temp. sensor

Inddor unit

send/receive

circuit

Relay
circuit

Noise

Filter

Converter

(AC

DC)

Clock

frequency

16MHz

High Power

factor Correction

circuit

Input current

sensor

Rotor position

detect circuit

Rotor position

detect circuit

• PWM synthesis function
• Input current release control
• IGBT over-current detect control
• Outdoor fan control
• High power factor correction control
• Inverter output frequency control
• A/D converter function
• P.M.V. control
• Discharge temp. control
• 4-way valve control
• Signal communication to indoor unit

M.C.U

For INDOOR UNIT

4-way

valve

P.M.V.

Inverter

(DC

AC)

Over current
detect circuit

Gate drive

circuit

Gate drive

circuit

Over current

sensor

Inverter

(DC

AC)

Outdoor

Fan motor

Compressor

MCC808 (P.C.B)

OUTDOOR UNIT

Advertising