8-1-8. Outdoor Fan Control (DC Fan Motor)

Although the outdoor fan motor drives the outdoor fan by non-step variable system of the revolution speed, the
revolution speed is restricted to three steps on the convenience of controlling. If a strong wind is lashing outside
of the room, the operation may be continued as the outdoor fan stops in order to protect the outdoor fan motor.

If a fan lock occurred due to entering of foreign matter, the air conditioner stops and an alarm is displayed.

<COOL, DRY>

Table 8-1-3

8-2. Description of Operation Circuit

• Turning [ON] the breaker flashes the operation lamp.

This is the display of power-ON (or notification of power failure).

• When pushing [START/STOP] button of the remote control, receive sound is issued from the main unit, and

the next operations are performed together with opening the vertical air flow louvers.

<HEAT>

Table 8-1-4

Model name

RAS-10YAV-E

RAS-13YAV-E

Compressor revolution (rps)

To 13,2

To 34,1

From 34,7

To 13,2

To 34,1

From 34,7

TO

38°C

450

800

800

450

940

940

TO < 38°C

450

630

800

450

700

940

Outdoor temp. sensor
TO

TO < 15°C

390

390

TO

38°C

450

630

800

450

700

940

TO < 38°C

450

450

630

450

450

700

ECONO. operation

TO < 15°C

390

390

TO is abnormal

630

630

800

700

700

940

Model name

RAS-10YAV-E

RAS-13YAV-E

Compressor revolution (rps)

To 16,2

To 44,3

From 44,9

To 16,2

To 44,3

From 44,9

TO

5°C

390

580

800

390

650

900

Outdoor temp. sensor
TO

TO < 5°C

580

580

800

650

650

940

TO

5°C

390

390

580

390

390

650

ECONO. operation

TO < 5°C

390

580

580

390

650

650

TO is abnormal

390

580

800

390

650

900