No.

Part name

T

Control board
assembly

Remarks

Procedure

1) Disconnect lead wires and connectors connected

from the control board assembly to other parts.
1. Lead wires

• Connection with terminal block :

3 wires (Black, White, Orange)

• Connection with compressor :

Remove the connector (3P).

• Connection with reactor :

Remove the relay connectors from P07, 08
(2P, White) and P12, 13 (2P, Yellow).

2. Connectors

CN300 : Outdoor fan (3P, White)
CN301 : Outdoor fan position detection

(5P, White)

CN701 : 4 valve (3P, Yellow)
CN600 : TE sensor (2P, White)
CN601 : TD sensor (3P, White)
CN603 : TS sensor (3P, White)
CN602 : TO sensor (2P, White)
CN500 : Case thermo. (2P, White)
CN703 : Pulse modulating valve (6P, White)

2) Remove the control board assembly from P.C.

board base.
1. Main control board assembly side

• Remove two claws of P.C. board base, and

remove upward the heat sink with hands.

• Remove three screws fixing the heat sink

and main control board assembly side, and
replace the board with a new one.

;

;

Reactor

U

Rear cabinet

1) Perform work of item 1 of

Q

, and

R

S

.

2) Remove fixed screws fixing to the bottom plate.

(ST1TØ4 x 10

l

3 pcs.)

3) Remove fixed screws fixing to the heat

exchanger. (ST1TØ4 x 10

l

2 pcs.)

4) Remove fixed screw fixing to the valve mounting

plate. (ST1TØ4 x 10

l

1 pc.)

CN300, CN301 and CN701, etc.
at the control board assembly
side are connectors with locks.
Therefore, remove the connector
while pushing the part indicated
by an arrow.

When mounting a new board,
check that the board is correctly
set in the groove of base holder
of P.C. board base.

CN701

CN500

CN703

CN301

P.C. board base

P.C. board

CN300

CN602

CN600

CN601

CN603

Advertising