Chapter 6 Basic Setting

VES-1616F-3x Series User’s Guide

81

Figure 25 VDSL Alarm Profile Setup

The following table describes the labels in this screen.

Table 15 VDSL Alarm Profile Setup

LABEL

DESCRIPTION

Name

Enter a descriptive name for identification purposes.

15 Minute LOFs

Threshold

Enter the number of Loss Of Framing seconds (LOFs) that are permitted to occur

within 15 minutes.

15 Minute LOSs

Threshold

Enter the number of Loss Of Signals seconds (LOSs) that are permitted to occur

within 15 minutes.

15 Minute LPRs

Threshold

Enter the number of Loss of PoweR seconds (LPRs) is permitted to occur within

15 minutes.

15 Minute LOLs

Threshold

Enter the number of Loss Of Link seconds (LOLs) that are permitted to occur

within 15 minutes.

15 Minute ESs

Threshold

Enter the number of Errored Seconds (ESs) that are permitted to occur within 15

minutes.

15 Minute SESs

Threshold

Enter the number of Severely Errored Seconds (SESs) that are permitted to occur

within 15 minutes.

15 Minute UASs

Threshold

Enter the number of UnAvailable Seconds (UASs) that are permitted to occur

within 15 minutes.

Initialization

Failure

Select On to trigger an alarm for an initialization failure trap.
Select Off to disable trap sending when a line fails to initialize.

Add

Click Add to save the new rule to the switch. It then displays in the summary table

at the bottom of the screen.

Cancel

Click Cancel to reset the fields to your previous configuration.

Clear

Click Clear to clear the fields to the factory defaults.

Name

This field displays the descriptive name for the alarm profile.

LOSs

This field displays the number of Loss Of Signal (LOS) seconds that are permitted

to occur within 15 minutes.

ESs

This field displays the number of Errored Seconds (ESs) that are permitted to

occur within 15 minutes.