Maintenance Instructions

WARNING

Before performing any maintenance, engine switch

should be in OFF position and spark plug wires

should be disconnected to prevent inadvertent op-

eration. Press foot valve or wand trigger to release

any fluid pressure in system.
Always wear safety glasses and gloves when per-

forming any maintenance to help protect against

drain chemicals and bacteria.

Cleaning

The hose should be cleaned as needed with hot, soapy

water and/or disinfectants. Do not allow water to enter

the engine or electrical system. Do not clean with pres-

sure washer. Wipe the unit down with a damp cloth.

Engine

Maintain the engine as directed in the engine opera-

tor’s manual supplied with the unit.

Pump Lubrication

Check the pump oil level prior to use. Place the jetter

on a level surface. Wipe any dirt and debris from the

area of the dipstick and remove the dipstick – check

the oil level. If needed, add SAE 30W non-detergent oil.

Do not overfill. Reinstall dipstick.
Change oil in pump after first 50 hours of operation

and every 500 hours of operation after that. With the

pump warm from operation, remove plug on bottom

of pump and drain oil into suitable container. Replace

plug. Fill with approximately 32 oz / 0,9 kg of SAE 30W

non-detergent oil using the checking procedure.

Gearbox Lubrication

Check the gearbox oil level prior to use. Place the jetter

on a level surface. Wipe any dirt and debris from the

area of the dipstick and remove the dipstick – check

the oil level. If needed, add SAE 90W gear lubricant. Do

not overfill. Reinstall dipstick.
Change oil in gearbox every 500 hours of operation.

With the gearbox warm from operation, remove plug

on bottom of gearbox and drain oil into suitable con-

tainer. Replace plug. Fill with approximately 8 oz /

0,2 kg of SAE 90W gear lubricant oil using the checking

procedure.

Preparing Pump for Cold Weather Storage

NOTICE

If the jetter will be stored under conditions

where the temperature is near or below 32°F / 0°C, the

jetter must be properly prepared. If water freezes in the

pump, it can damage it.
There are two methods for preparing the jetter for cold

weather storage. The first is to open all valves in the sys-

tem and use compressed air to force any water out of

the system. This can also be used to remove water from

the hoses.
The second method uses RV antifreeze (non-ethylene

glycol antifreeze). Do not use ethylene glycol antifreeze

in the jetter pump. Ethylene glycol cannot be used in

drainage systems.

1. Attach a 3’ / 90 cm section of hose to the inlet supply

valve and open valve.

2. Place the end of the hose into the container of RV

antifreeze.

3. Remove the nozzle from the end of the hose.
4. Start the jetter and run until antifreeze comes out of

the end of the hose.

Accessories