10.4” Industrial Fanless Panel PC

Minimum Value: 0°C
Maximum Value: 127°C

CPU Fan Start PWM [070]

The Fan 3 Start PWM option can only be set if the CPU FAN Mode Setting option is set to Automatic
Mode. Use the Fan 3 Start PWM option to select the PWM mode the fan starts to rotate with after the
temperature specified in the Temperature 3 Limit of Start is exceeded. The Super I/O chipset supports 128
PWM modes. To select a value, select the Fan 3 Start PWM option and enter a decimal number between
000 and 127. The temperature range is specified below.

PWM Minimum Mode: 0
PWM Maximum Mode: 127

Slope PWM [0.5 PWM]

The Slope PWM 1 option can only be set if the CPU FAN Mode Setting option is set to Automatic Mode.
Use the Slope PWM 1 option to select the linear rate at which the PWM mode increases with respect to an
increase in temperature. A list of available options is shown below:

0 PWM
1 PWM
2 PWM
4 PWM
8 PWM
16 PWM
32 PWM
64 PWM

The following system parameters and values are shown. The system parameters that are monitored are:

System Temperatures: The following system temperatures are monitored
o CPU Temperature
o System Temperature

Fan Speeds: The CPU cooling fan speed is monitored.

o CPU Fan Speed

Voltages: The following system voltages are monitored

o CPU Core
o +1.05V o +3.30V o +12.0 V o +1.5V
o +1.8V o 5VSB o VBAT

Advertising