Fuel, Specifications – Grain Systems PNEG-1797 User Manual

Page 21

Advertising
background image

3. Specifications

PNEG-1797CE CE Approved T-Series Tower Dryer

21

Minimum Electrical Power Requirements

Fuel

1. Fuel types are LPG or natural gas vapor.

2. Minimum supply pressure is,

a. 350 mBar natural gas at full burner flow rate.

b. 350 mBar LPG vapor at full burner flow rate. Higher pressures may be required to obtain

maximum burner output.

3. Burner flow rates are as table on

Page 22

.

3 Phase Power Requirements (A)

Supply Voltage

230

380

400

415

440

460

575

Model #

T-1050

204

123

117

113

106

102

81

T-1260

226

136

130

125

118

113

90

T-1575

258

156

148

143

135

129

103

T-1875

258

156

148

143

135

129

103

T-20100

316

191

181

175

165

158

126

T-24100

316

191

181

175

165

158

126

F-1050

204

123

117

113

106

102

81

F-1260

226

136

130

125

118

113

90

F-1575

258

156

148

143

135

129

103

F-1875

258

156

148

143

135

129

103

F-20100

316

191

181

175

165

158

126

F-24100

316

191

181

175

165

158

126

Advertising