Specifications – Grain Systems PNEG-1797 User Manual

Page 22

Advertising
background image

3. Specifications

22

PNEG-1797CE CE Approved T-Series Tower Dryer

T-Series and F-Series Fuel Specifications

T-Series and F-Series

T/F-1050

T/F-1260

T/F-1575

T/F-1875

T/F-1054

T/F-20100

T/F-24100

Maximum Burner
Output (kW)

3254

3831

4882

5180

6244

6858

7722

Average Burner
Output (kW)

1871

2203

2807

2979

3590

3943

4440

LPG Fuel

LPG Gross CV

93.8 MJ/m

3

Maximum Gas Flow

LPG (m

3

/h)

125

147

187

199

240

263

296

Average Gas Flow

LPG (m

3

/h)

72

85

108

114

138

151

170

Supply Pressure (mBar

1

)

350-700

350-700

350-700

350-700

350-700

350-700

350-700

Regulator Setting (mBar

2

)

206

206

206

206

206

206

Regulator Spring

Black

Cadmium

Cadmium

Cadmium

Cadmium

Cadmium

Cadmium

Burner Pressure High-Fire

mm (H

2

O

6

)

418

1375

807

1189

1447

972

Burner Pressure Low-Fire

mm (H

2

O

7

)

16.7

55.0

32.3

47.5

57.9

38.9

Natural Gas Fuel

NG Gross CV

39 MJ/m

3

Maximum Gas Flow

NG (m

3

/h)

303

357

455

483

582

640

720

Average Gas Flow

NG (m

3

/h)

174

205

262

278

335

368

414

Supply Pressure (mBar

1

)

350-700

350-700

350-700

350-700

350-700

350-700

350-700

Regulator Setting (mBar

2

)

21

206

206

206

206

206

206

Regulator Spring

Black

Cadmium

Cadmium

Cadmium

Cadmium

Cadmium

Cadmium

Burner Pressure High-Fire

mm (H

2

O

6

)

719

1189

697

1009

1241

855

Burner Pressure Low-Fire

mm (H

2

O

7

)

28.8

47.6

27.9

40.3

49.7

34.2

Pressure Relief

Set Point (mBar

4

)

500

500

500

500

500

500

500

Over Pressure Valve

Set Point (mBar

5

)

450

450

450

450

450

450

450

Advertising