Error messages, Chapter 12 error messages, Safety circuit shut down messages – Grain Systems PNEG-1797 User Manual

Page 69: Fan/heater generated errors

Advertising
background image

PNEG-1797CE CE Approved T-Series Tower Dryer

69

12. Error Messages

Safety Circuit Shut Down Messages

Shut down warning window: Touch the Help button to display the shut down help window.

(See Figure 12A.)

Figure 12A

Fan/Heater Generated Errors

Air Switch Stuck

Switch is stuck closed when fan is OFF.

Fan Loss of Airflow

Air switch has stopped sensing air pressure during fan operation.

Fan No Airflow

Air switch is not sensing air pressure after fan start-up.

Flame Loss

Flame signal was lost during burner operation.

Grain Temp Short

Grain temperature sensor is showing short circuit.

Grain Overheat

Grain temperature has exceeded 100°C. Grain flow may be blocked or metering speed too slow. This
re-sets once cooled, but the burner must be re-cycled to enable re-start.

Shut down warning window:
Touch the Help button
to display the shut down
help window.