8. Dryer Start-Up and Operation

PNEG-1797CE CE Approved T-Series Tower Dryer

55

9. Set minimum unload rate to 10% and maximum to suit the unload equipment.

10. Set plenum temperature management ON to reduce risk of over-drying when unload rates are limited

by a low maximum unloading rate.

11. Return to Moisture Control window and set grain type. Optional printer may also be setup.

Figure 8B

12. Turn UNLOAD switch OFF.

13. Open fuel supply.

14. Turn LOAD AUGER switch to AUTO.

15. Refer to drying tables

on Pages 59-64

. Select the initial unload rate for the dryer model, drying

temperature and moisture content. Example: Model 1575 drying wheat from 18% to 13% at 80°C
initial unload rate = 60.

16. Turn FAN to ON.

17. Turn HEATER to ON.

18. If the dryer is filled with wet grain, let the fan and heater run for 6 minutes per 1% of moisture to

be removed.

Example: 18% - 13% = 5% removal. Time = 5 (%) x 6 (min.) = 30 minutes.

This step is only required at initial start-up. Re-starting with dry grain, omit this step.

19. Then, turn UNLOAD AUGER to MANUAL and set the METER ROLL SPEED, (MANUAL SPEED).

To do this push on the meter roll adjustment knob and turn to set initial unload rate. Grain should
start to run.

7. Accept

6. Set grain type.
Bin # is for
reference only.