12. Error Messages

PNEG-1797CE CE Approved T-Series Tower Dryer

71

Unload Motor Overload

The motor overload has tripped on the unload motor overload located in the upper control box.

User Safety

On CE dryers this safety indicates that the valve proving system has failed to prove the main safety valves.
Valves may need to be replaced or be re-seated.

Master Display Generated Errors

Cont-Batch Mode Chng

Dryer was switch from continuous flow to batch or vice versa whilst running.

Network Failed FH x

Network communications have been lost to the Fan/Heater board. Check cables.

(See Figure 12B.)

Network Failed Input/Output

Network connections have been lost between the Main I/O and Lower control box board. Check cables.

Network Failed Mast

Network connections have been lost between Master Display board (lower control panel) and Input/Output
board (upper control panel door) and the Fan/Heater boards. Check cables.

Figure 12B

Plenum Temp Open x

Plenum temperature sensor is showing open circuit.

Plenum Temp Short x

Plenum temperature sensor is showing short circuit.

Plenum x Overheat

Plenum has exceeded 154°C and burner has locked out.