8. Dryer Start-Up and Operation

56

PNEG-1797CE CE Approved T-Series Tower Dryer

Figure 8C

20. Take three (3) samples with an accurate moisture meter and calculate the average moisture.

Calibrate the wet and dry grain sensors until the on screen reading agrees with the average.
To do this:

a. Press

.

b. Press

.

c. Calculate difference between actual moisture reading an that on screen.

d. Increase or decrease the on screen reading by the calculated difference.

Example:

Actual = 17%;

On screen = 18.3%.

Difference = Actual - On screen = -1.3%

Enter -1.3% in the calibration screen.