Select data log sample time – Grain Systems PNEG-1797 User Manual

Page 33

Advertising
background image

6. Vision Touch Screen Display

PNEG-1797CE CE Approved T-Series Tower Dryer

33

1. Dryer operation animation shows the status of the fan/heaters, load and unload augers and meter

rolls. Also grain temperature, moisture content, M/C set point and tones counter.

2. Dryer status indicates if the dryer is stopped, started, loading or unloading.

3. Dryer status chart shows the grain temperature, moisture in/out, temperature out and metering roll

speed. Over a period of time.

4. Plenum shows the plenum temperature set point (SP), actual plenum temperature and

burner status.

5. Setup buttons provides access to timers, temperature set points, dryer model and moisture

control setup.

Figure 6C

Select Data Log Sample Time

To change the sample time:

1. Press modify.

2. Select required time.

3. Press Accept/Exit.

To clear the table, press Clear Table button.

(See Figure 6C.)