7. Dryer Start-Up

46

PNEG-1797CE CE Approved T-Series Tower Dryer

Pre-Season Checks

1. Inspect the accutrol metering system.

a. Open the two (2) access doors and inspect the sweep metering system to ensure that the system

is able to move freely.

2. Gas train

a. Check for any leaks by pressurizing the line with air and using gas leak disclosing solution or by

doing pressure loss tests.

b. Leaks must be rectified by opening and resealing the joint.

3. Wiring

a. Check wiring on the dryer and inside the control panels for signs of damage or loose connections.

Rectify any faults.

4. Electrical power

a. Check all circuit breakers in the panel are closed.

b. Turn ON the electrical power supply to the dryer.

c. Check for correct voltage on all phases.

5. CONTROL POWER switch

a. Turn the CONTROL POWER switch to ON.

b. At boot screen appears

(See Figure 6A on Page 32)

, press

.

c. Any faults will be displayed on the Main screen.

d. If no faults are found safe, the START switch will illuminate.