13

Grain Systems, Inc. Assumption, Ill.

18' Manual Batch

SIDE VIEW

4.00"

5/16" X 3/4" BIN BOLT
(S-275)

Figure #11

DETAIL "A"

DETAIL "A"

TOP STIFFENER

FRONT VIEW

BOLT HEAD AND SEALING
WASHER MUST BE ON THE
INSIDE OF THE BIN.

TOP STIFFENER STARTING LOCATION

Refer to Figure #11, for proper location of top stiffeners. On the overlap of the stiffeners, and on the splice, use

3/8" x 1" hex bolts, a washer on the nut side connection. Refer to the stiffener layout, Figure #9, for stiffener usage.

All stiffeners are outside the bin wall. Use 5/16" x 3/4" Grade 5 bin bolts with head and neoprene washer to the inside

of the bin wall. Refer to proper charts and illustrations on the previous two pages for proper location of stiffeners and

sidewall sheets.

REV. 9-30-96