Grain Systems PNEG-365 User Manual
Page 13
Advertising
13
Grain Systems, Inc. Assumption, Ill.
18' Manual Batch
SIDE VIEW
4.00"
5/16" X 3/4" BIN BOLT
(S-275)
Figure #11
DETAIL "A"
DETAIL "A"
TOP STIFFENER
FRONT VIEW
BOLT HEAD AND SEALING
WASHER MUST BE ON THE
INSIDE OF THE BIN.
TOP STIFFENER STARTING LOCATION
Refer to Figure #11, for proper location of top stiffeners. On the overlap of the stiffeners, and on the splice, use
3/8" x 1" hex bolts, a washer on the nut side connection. Refer to the stiffener layout, Figure #9, for stiffener usage.
All stiffeners are outside the bin wall. Use 5/16" x 3/4" Grade 5 bin bolts with head and neoprene washer to the inside
of the bin wall. Refer to proper charts and illustrations on the previous two pages for proper location of stiffeners and
sidewall sheets.
REV. 9-30-96