Response:

NR2

Considerations:

1) The MAXimum offset is dependent on the amplitude.
2) The MAX and MIN arguments should not be used in a
program message containing an AMPLitude command,
since these values are evaluated during parsing, based on
the current value of the amplitude.


FUNCtion

The function command is used to set the type of waveform
to be generated by the instrument.

Command Type: Setting or Query
Setting Syntax: FUNCtion<ws><SIN|SQU|TRI>
Examples:

FUNC SIN

FUNC TRI
Query Syntax: FUNCtion?
Examples:

FUNC?

Response: SIN|TRI|SQU

DCYCle <duty cycle value>

This command is used to set the duty-cycle of the square
wave or the symmetry of triangular wave. The value is
given in percent .

Arguments Type:

Numeric

Units:

None (percent implied)